LOG PAGE 3H - READ ERRORS
This page enables the host to extract the number of flash READ commands which have failed to
complete successfully. Should a READ command fail, the only course of action is to retry the READ.
Errors corrected without delay are READ errors which have completed the ECC correction. This
information is provided since the Power On or Last Parameter Reset.
76 - 77 Parameter Code = 0006h (Total Uncorrected Errors)
78 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
79 Parameter Length = 08h
80 - 87 Total Uncorrected Errors
88 - 89 Parameter Code = 8000h (Vendor Unique - Flash Write Commands)
90 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
91 Parameter Length = 08h
92 - 99 Flash Write Commands
Bit
Byte76543210
0 Reserved Page Code = 03h
1 Reserved
2 - 3 Page Length = 0060h
4 - 5 Parameter Code = 0000h (Errors Corrected without Delays)
6 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
7 Parameter Length = 08h
8 - 15 Errors Corrected without Delays
16 - 17 Parameter Code = 0001h (Errors Corrected with Possible Delays)
18 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
19 Parameter Length = 08h
20 - 27 Errors Corrected with Possible Delays
28 - 29 Parameter Code = 0002h (Total Re-Reads)
30 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
31 Parameter Length = 08h
32 - 39 Total Re-Reads
40 - 41 Parameter Code = 0003h (Total Errors Corrected)
42 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
43 Parameter Length = 08h
44 - 51 Total Errors Corrected